3M

3M™ Aura™ 9322A+ P2 / FFP2 Valved Particulate Respirator - Box of 10

SKU: HMS-002

$79.95 incl. GST

3M Aura 9322A+ valved P2 / FFP2 flat-fold particulate respirator with 3M Cool Flow valve, low breathing resistance and individually packaged respirators. Box of 10.

Key features

  • P2 particulate respirator
  • FFP2 classification shown by 3M for the 9322A+
  • 3M™ Cool Flow™ exhalation valve helps release heat build-up
  • Low breathing resistance using 3M electret particulate filter material
  • Three-panel Aura flat-fold design accommodates facial movement
  • Embossed upper panel helps reduce eyewear fogging
  • Sculpted low-profile nose panel supports field of vision and eyewear compatibility
  • Soft nose foam and smooth inner cover web for wearer comfort
  • Innovative chin tab assists donning and adjustment
  • Headband material helps distribute strap pressure
  • Individually packaged for hygienic storage before use
  • Foldable design for convenient storage

Product information

The 3M Aura 9322A+ is a disposable P2 / FFP2 valved particulate respirator designed for comfortable respiratory protection against suitable airborne particulates. Its three-panel flat-fold design is made to accommodate facial movement and a range of face shapes, while the 3M Cool Flow valve helps release heat build-up for cooler, more comfortable wear. The sculpted nose panel, soft nose foam, low-profile shape and embossed upper panel are designed to support fit, field of vision and eyewear compatibility. Each respirator is individually packaged before use.

Brand3M
Product typeP2 / FFP2 valved particulate respirator
Pack sizeBox of 10
StyleFlat-fold / headband / valved
Store SKUHMS-002
Packed weight0.22 kg

Standards & classification

3M identifies the 9322A+ as a P2 / FFP2 particulate respirator. 3M Australian material for the 9300 series states compliance with AS/NZS 1716 for P2 models and recommends fit testing in accordance with AS/NZS 1715 as part of an appropriate respiratory protection program. The manufacturer lists Fluid Resistant (ASTM F1862): No and Exhalation Valve: Yes for this model.

Fit & sizing guidance

The 9322A+ is a standard-size, tight-fitting headband respirator. The Aura three-panel design is intended to fit a wide range of face shapes and sizes while accommodating facial movement. The sculpted nose panel, soft nose foam and headbands assist positioning and comfort. A good seal between the respirator and the face is essential. Facial hair or other conditions that interfere with the sealing surface can prevent an adequate seal. Where respiratory protection is required in a workplace, fit testing should form part of the applicable respiratory protection program.

Directions for use

Before fitting, ensure hands are clean and inspect the respirator and its components for damage.

1. Open the flat-fold respirator fully so the upper and lower panels are completely unfolded.
2. Hold the respirator with the nosepiece uppermost and position it under the chin.
3. Pull the headbands over the head. Position the upper strap on the crown of the head and the lower strap below the ears. Do not twist the straps.
4. Adjust the upper and lower panels and use the chin tab to position the respirator comfortably.
5. Using both hands, mould the nose clip around the nose and cheeks to help achieve a close fit.
6. Perform a user seal check before entering the area where respiratory protection is required.

Always read and follow the current 3M user instructions supplied with the respirator.

Warnings & use limitations

Do not use for

Storage

Keep unused respirators in their individual packaging and outer box in clean, dry storage conditions. Protect from contamination before use. Check the expiry/use-by information printed on the packaging and follow any storage temperature and humidity limits stated by 3M on the current packaging or user instructions.

Specifications

Brand3M™
ModelAura™ 9322A+
3M Product Number9322A+
3M ID7100106887
Filter classP2
European classification shown by 3MFFP2
Exhalation valveYes
Valve type3M™ Cool Flow™ valve
Respirator styleFlat fold / three panel
Respirator sizeStandard
Fluid resistant (ASTM F1862)No
Flame resistance (ASTM D2859-96)No
Filter technology3M electret particulate filter material with low breathing resistance technology
Individual packagingYes
Retail pack sizeBox of 10
Manufacturer case quantity120 respirators (12 boxes of 10)

Frequently asked questions

Is the 3M Aura 9322A+ a P2 respirator?

Yes. 3M identifies the 9322A+ as a P2 particulate respirator and also shows FFP2 classification for this model.

Does the 9322A+ have an exhalation valve?

Yes. It uses the 3M Cool Flow valve, which is designed to help release heat build-up for cooler and more comfortable wear.

How many respirators are in an HMS box?

HMS sells the 9322A+ in boxes of 10 respirators. The 3M outer case contains 120 respirators, equivalent to 12 boxes of 10.

Is the 9322A+ fluid resistant?

No. 3M lists Fluid Resistant (ASTM F1862) as No for this model.

What is the difference between the 9322A+ and the 9320A+?

Both use the 3M Aura three-panel flat-fold design and are P2 / FFP2 particulate respirators. The key difference is that the 9322A+ has a 3M Cool Flow exhalation valve, while the 9320A+ is unvalved.

What is the difference between the 9322A+ and the 1870+?

The 9322A+ is a valved P2 / FFP2 particulate respirator intended for suitable particulate hazards. The 1870+ is an unvalved N95 health care particulate respirator and surgical mask with manufacturer-stated fluid-resistance and bacterial-filtration claims. Those health care/surgical claims should not be assumed for the 9322A+.

Can facial hair affect the fit of the 9322A+?

Yes. Facial hair in the sealing area can interfere with the seal of a tight-fitting respirator.

Does the 9322A+ protect against gases and vapours?

No. This is a particulate respirator and should not be used for gases or vapours unless the manufacturer specifically states otherwise for the application.

Important product information

Respirator selection, fit and use depend on the hazard, workplace conditions and the wearer. Read and follow the manufacturer’s instructions supplied with the product. Where respiratory protection is required for work, follow the applicable workplace respiratory protection program and fit-testing requirements.