The 3M Aura 9322A+ is a disposable P2 / FFP2 valved particulate respirator designed for comfortable respiratory protection against suitable airborne particulates. Its three-panel flat-fold design is made to accommodate facial movement and a range of face shapes, while the 3M Cool Flow valve helps release heat build-up for cooler, more comfortable wear. The sculpted nose panel, soft nose foam, low-profile shape and embossed upper panel are designed to support fit, field of vision and eyewear compatibility. Each respirator is individually packaged before use.
3M identifies the 9322A+ as a P2 / FFP2 particulate respirator. 3M Australian material for the 9300 series states compliance with AS/NZS 1716 for P2 models and recommends fit testing in accordance with AS/NZS 1715 as part of an appropriate respiratory protection program. The manufacturer lists Fluid Resistant (ASTM F1862): No and Exhalation Valve: Yes for this model.
Fit & sizing guidance
The 9322A+ is a standard-size, tight-fitting headband respirator. The Aura three-panel design is intended to fit a wide range of face shapes and sizes while accommodating facial movement. The sculpted nose panel, soft nose foam and headbands assist positioning and comfort. A good seal between the respirator and the face is essential. Facial hair or other conditions that interfere with the sealing surface can prevent an adequate seal. Where respiratory protection is required in a workplace, fit testing should form part of the applicable respiratory protection program.
Directions for use
Before fitting, ensure hands are clean and inspect the respirator and its components for damage.
1. Open the flat-fold respirator fully so the upper and lower panels are completely unfolded.
2. Hold the respirator with the nosepiece uppermost and position it under the chin.
3. Pull the headbands over the head. Position the upper strap on the crown of the head and the lower strap below the ears. Do not twist the straps.
4. Adjust the upper and lower panels and use the chin tab to position the respirator comfortably.
5. Using both hands, mould the nose clip around the nose and cheeks to help achieve a close fit.
6. Perform a user seal check before entering the area where respiratory protection is required.
Always read and follow the current 3M user instructions supplied with the respirator.
Warnings & use limitations
Proper respirator selection, training, fitting and use are essential. Read and understand the manufacturer user instructions before use.
Inspect the respirator before each use and discard it if damaged, soiled or otherwise unsuitable.
A tight facial seal is required for effective respiratory protection.
Facial hair in the sealing area can interfere with the face seal.
This product is a particulate respirator and should not be assumed to provide protection against gases or vapours.
3M lists this model as not fluid resistant under ASTM F1862.
The exhalation valve is intended to help reduce heat build-up and does not change the need for correct respirator selection and fitting.
Respiratory protective equipment should be selected by a competent person with knowledge of the actual working conditions and equipment limitations.
Misuse of a respirator can result in sickness or death.
Do not use for
Gases or vapours unless separately stated by the manufacturer.
Oxygen-deficient atmospheres.
Unknown contaminant concentrations or conditions immediately dangerous to life or health.
Applications requiring a fluid-resistant surgical respirator or surgical mask rating; 3M lists ASTM F1862 fluid resistance as No for the 9322A+.
Any application outside the limitations stated in the current 3M packaging and user instructions.
Storage
Keep unused respirators in their individual packaging and outer box in clean, dry storage conditions. Protect from contamination before use. Check the expiry/use-by information printed on the packaging and follow any storage temperature and humidity limits stated by 3M on the current packaging or user instructions.
Specifications
Brand3M™
ModelAura™ 9322A+
3M Product Number9322A+
3M ID7100106887
Filter classP2
European classification shown by 3MFFP2
Exhalation valveYes
Valve type3M™ Cool Flow™ valve
Respirator styleFlat fold / three panel
Respirator sizeStandard
Fluid resistant (ASTM F1862)No
Flame resistance (ASTM D2859-96)No
Filter technology3M electret particulate filter material with low breathing resistance technology
Individual packagingYes
Retail pack sizeBox of 10
Manufacturer case quantity120 respirators (12 boxes of 10)
Frequently asked questions
Is the 3M Aura 9322A+ a P2 respirator?
Yes. 3M identifies the 9322A+ as a P2 particulate respirator and also shows FFP2 classification for this model.
Does the 9322A+ have an exhalation valve?
Yes. It uses the 3M Cool Flow valve, which is designed to help release heat build-up for cooler and more comfortable wear.
How many respirators are in an HMS box?
HMS sells the 9322A+ in boxes of 10 respirators. The 3M outer case contains 120 respirators, equivalent to 12 boxes of 10.
Is the 9322A+ fluid resistant?
No. 3M lists Fluid Resistant (ASTM F1862) as No for this model.
What is the difference between the 9322A+ and the 9320A+?
Both use the 3M Aura three-panel flat-fold design and are P2 / FFP2 particulate respirators. The key difference is that the 9322A+ has a 3M Cool Flow exhalation valve, while the 9320A+ is unvalved.
What is the difference between the 9322A+ and the 1870+?
The 9322A+ is a valved P2 / FFP2 particulate respirator intended for suitable particulate hazards. The 1870+ is an unvalved N95 health care particulate respirator and surgical mask with manufacturer-stated fluid-resistance and bacterial-filtration claims. Those health care/surgical claims should not be assumed for the 9322A+.
Can facial hair affect the fit of the 9322A+?
Yes. Facial hair in the sealing area can interfere with the seal of a tight-fitting respirator.
Does the 9322A+ protect against gases and vapours?
No. This is a particulate respirator and should not be used for gases or vapours unless the manufacturer specifically states otherwise for the application.
Important product information
Respirator selection, fit and use depend on the hazard, workplace conditions and the wearer. Read and follow the manufacturer’s instructions supplied with the product. Where respiratory protection is required for work, follow the applicable workplace respiratory protection program and fit-testing requirements.