Canadian-made Vitacore CAN99™ Black headband respirator with >99% filtration, 99PFE-L3 performance, ASTM Level 3 fluid resistance and an adjustable aluminium nosepiece. Available in HMS pack-size variants.
Key features
Greater than 99% filtration according to Vitacore
99PFE-L3 performance
Described by Vitacore as an N95 or N99 Surgical Respirator Equivalent
ASTM Level 3 fluid resistance
Greater than 160 mmHg blood penetration resistance
Headband design intended to support a close facial seal
Fully aluminium adjustable nosepiece
Aluminium nosepiece described by Vitacore as MRI compatible
The Vitacore CAN99™ Black is a Canadian-made disposable headband respirator designed to combine high particulate filtration with a close facial seal and comfortable breathing performance. Vitacore describes the CAN99 Black as an N95 or N99 surgical respirator equivalent with 99PFE-L3 performance and greater than 99% filtration. The respirator uses a headband fitting system and a fully aluminium nosepiece to assist positioning and seal around the nose. It is also rated by the manufacturer as ASTM Level 3 for fluid resistance, with greater than 160 mmHg blood penetration resistance. The black design provides an alternative to conventional white respirators while retaining a professional headband-style fit. CAN99 Black respirators are manufactured in Canada and are graphene-free.
Pack size10 or 25 respirators depending on selected variant
StyleHeadband / non-valved / black
Store SKUHMS-004
Packed weightTo be confirmed
Standards & classification
Vitacore describes the CAN99™ Black as an "N95 or N99 Surgical Respirator Equivalent (99PFE-L3)" and states greater than 99% filtration. The manufacturer also specifies ASTM Level 3 performance with greater than 160 mmHg blood penetration resistance.
HMS does not represent this exact CAN99 Black model as a NIOSH-certified N95 unless such certification is specifically documented by the manufacturer for this product. The manufacturer wording above should therefore be distinguished from a formal NIOSH N95 approval claim.
Fit & sizing guidance
The CAN99 Black is a tight-fitting headband respirator. Both headbands should be positioned correctly so the respirator sits securely against the face, and the aluminium nosepiece should be moulded around the nose to assist the seal.
A close seal between the respirator and the face is important for effective respiratory protection. Facial hair, jewellery, eyewear or other items that interfere with the sealing surface may prevent an adequate seal.
Check the fit each time the respirator is worn. Where respirators are required for occupational use, selection and fit testing should form part of the workplace respiratory protection program and applicable safety requirements.
Directions for use
Before use, inspect the respirator and headbands for damage, contamination or deterioration.
1. Hold and open the respirator so it can be positioned comfortably over the nose, mouth and chin.
2. Position the respirator against the face with the nosepiece at the top.
3. Pull the headbands over the head and position them so the respirator is held securely against the face.
4. Adjust the respirator around the chin and sides of the face.
5. Using both hands, mould the aluminium nosepiece around the nose and cheeks to help create a close fit.
6. Check the facial seal before entering an area where respiratory protection is required.
7. Reposition the respirator and headbands if leakage is detected around the edges.
Always follow the current instructions supplied by Vitacore with the respirator and any applicable workplace respiratory protection procedures.
Warnings & use limitations
Correct respirator selection, fitting and use are essential.
A tight facial seal is required for effective respiratory protection. Facial hair or other objects beneath the sealing surface can interfere with the seal.
Inspect the respirator before use. Do not use a respirator that is damaged, contaminated or otherwise unsuitable.
This product is primarily a particulate respirator. Do not assume protection against gases, vapours or other hazards unless specifically stated by the manufacturer for the intended application.
The manufacturer describes the CAN99 Black as an N95 or N99 Surgical Respirator Equivalent (99PFE-L3). This wording should not be interpreted as an HMS claim that this exact black model carries a NIOSH N95 approval.
Respiratory protective equipment should be selected according to the actual hazard, contaminant concentration, working conditions and applicable safety requirements.
Do not rely on a respirator where the atmosphere may be immediately dangerous to life or health or where oxygen levels are inadequate.
Improper selection, fitting or use of respiratory protection can result in serious illness or death.
Do not use for
Oxygen-deficient atmospheres.
Unknown contaminant concentrations or conditions immediately dangerous to life or health.
Gases or vapours unless the manufacturer specifically states that the respirator is suitable for the particular hazard.
Applications requiring a specific regulatory certification that has not been verified for this exact CAN99 Black model.
Use where facial hair or another obstruction prevents an adequate facial seal.
Any application outside the limitations contained in the current Vitacore instructions or applicable workplace respiratory protection requirements.
Storage
Store unused CAN99 Black respirators in a clean, dry location and protect them from contamination, physical damage, excessive moisture, direct sunlight and extreme temperatures. Keep respirators in their original box or suitable protective packaging until required for use. Inspect the respirator before use and follow any expiry, storage or handling information printed on the current Vitacore packaging.
Specifications
BrandVitacore
ProductCAN99™ Black
Product typeHeadband particulate respirator
ColourBlack
Filtration>99% according to Vitacore
Performance description99PFE-L3
Manufacturer classification wordingN95 or N99 Surgical Respirator Equivalent
Fluid resistanceASTM Level 3
Blood penetration resistance>160 mmHg
Head attachmentHeadbands
Exhalation valveNo
NosepieceFully aluminium
MRI compatibilityAluminium nosepiece described by Vitacore as MRI compatible
GrapheneGraphene-free
Country of manufactureCanada
Individual packagingNo
HMS pack variants10 respirators or 25 respirators
Currently stocked HMS primary variantBox of 25
Frequently asked questions
What filtration level does the CAN99 Black provide?
Vitacore states that the CAN99 Black provides greater than 99% filtration and describes the product as 99PFE-L3.
Is the CAN99 Black a NIOSH-certified N95?
Vitacore describes this exact black product as an "N95 or N99 Surgical Respirator Equivalent (99PFE-L3)". HMS does not describe the CAN99 Black as NIOSH-certified unless formal NIOSH approval for this exact model is specifically documented by the manufacturer.
Is the CAN99 Black fluid resistant?
Yes. Vitacore states that the CAN99 Black has ASTM Level 3 fluid resistance with greater than 160 mmHg blood penetration resistance.
Does the CAN99 Black use ear loops or headbands?
It uses headbands. The headband design is intended to help achieve a close-fitting respirator seal.
Does the CAN99 Black have an exhalation valve?
No. The CAN99 Black supplied by HMS is a non-valved headband respirator.
How many CAN99 Black respirators are in a box?
HMS has variants for 10 and 25 respirators. The currently stocked primary option is the box of 25.
Are CAN99 Black respirators individually wrapped?
No. The Australian supplier information for this product states that the respirators are not individually wrapped.
Where is the CAN99 Black manufactured?
Vitacore states that the respirator is made in Canada.
Does the CAN99 Black contain graphene?
Vitacore states that the CAN99 Black is graphene-free.
Is the aluminium nosepiece MRI compatible?
Vitacore describes the fully aluminium nosepiece as MRI compatible. Suitability for a particular medical environment should still be confirmed under that facility's procedures.
Can facial hair affect the fit?
Yes. Facial hair in the area where a tight-fitting respirator seals against the face can interfere with the seal.
Does the CAN99 Black protect against gases and vapours?
It should not be assumed to protect against gases or vapours. Respirator selection must match the specific hazard and the manufacturer's stated limitations.
Important product information
Respirator selection, fit and use depend on the hazard, workplace conditions and the wearer. Read and follow the manufacturer’s instructions supplied with the product. Where respiratory protection is required for work, follow the applicable workplace respiratory protection program and fit-testing requirements.