Trident

TRIDENT® Flat Fold P2 Pink Valved Respirator - Box of 20

SKU: HMS-011

$125.50 incl. GST

Pink TRIDENT® P2 valved flat-fold respirator with three-panel construction, adjustable foam nose seal, low breathing resistance and an exhalation valve to reduce heat and moisture build-up. Box of 20.

Key features

  • Certified P2 particulate respirator
  • AS/NZS 1716:2012 P2 respiratory protection
  • Distinctive pink respirator design
  • Exhalation valve helps reduce heat and moisture build-up
  • Advanced multilayer particulate filtration technology
  • Designed for suitable mechanically and thermally generated particulates
  • Suitable particulate types include dusts, mists, fumes and smoke within manufacturer limitations
  • Three-panel flat-fold construction
  • Three-panel design provides structural integrity and a form-fitting seal
  • Proprietary adjustable foam nose seal
  • Foam nose seal helps reduce eyewear fogging
  • Low breathing resistance
  • Designed for wearer comfort
  • Headband fitting system
  • Designed for use with other appropriate PPE
  • Latex free
  • Individually batch numbered
  • Individually packaged
  • Box of 20

Product information

The TRIDENT® Flat Fold P2 Pink Valved Respirator combines certified P2 particulate respiratory protection with a distinctive pink finish and a valved three-panel design. Advanced multilayer filtration is designed for protection against suitable mechanically and thermally generated particulates including dusts, mists, fumes and smoke. The exhalation valve helps reduce heat and moisture build-up within the breathing zone, while the three-panel construction provides structural integrity, facial conformity and wearer comfort. A proprietary adjustable foam nose seal assists facial sealing and helps reduce eyewear fogging. The respirator offers low breathing resistance, is latex free and is individually packaged for hygiene and traceability. HMS supplies the Pink P2 Valved Respirator in boxes of 20.

BrandTrident
Product typeP2 pink valved particulate respirator
Pack sizeBox of 20
StyleThree-panel flat-fold / headband / valved
Store SKUHMS-011
Packed weight0.39 kg

Standards & classification

The TRIDENT® P2 Valved Disposable Respirator platform is certified to AS/NZS 1716:2012 as a P2 particulate respirator.

Trident identifies certification ID BMP 732382 for its P2 valved respirator family.

The exact Pink model is identified by Australian supplier Industree Group as TRIDENT® Flat Fold P2 Pink Valved Respirator, product code RTCFFP2VP.

HMS uses P2 as the verified Australian respirator classification for this product. The Pink model should not be assumed to carry surgical-mask, Level 3 or other healthcare classifications unless those additional claims are specifically documented for this exact model.

Fit & sizing guidance

The TRIDENT Pink P2 Valved Respirator is a tight-fitting headband respirator. Correct positioning of the three-panel respirator, head straps and adjustable foam nose seal is important for achieving an effective facial seal.

Open the upper and lower panels fully and position the lower panel beneath the chin. The upper panel and foam nose seal should sit over the nose bridge and beneath the eyes. Position the upper head strap at the crown of the head and the lower strap below the ears at the back of the neck without crossing or twisting the straps.

Using both hands, mould the foam nose seal around the nose bridge and cheeks.

A close facial seal is essential for effective respiratory protection. Facial hair within the sealing area can interfere with the seal. Trident recommends that wearers be clean-shaven where the respirator contacts the face.

Perform a fit check each time the respirator is fitted. Where respiratory protection is required occupationally, appropriate fit testing should form part of the workplace respiratory protection program in accordance with AS/NZS 1715 and applicable workplace requirements.

Directions for use

Always read and follow the current TRIDENT wearer instructions supplied with the respirator.

Before fitting, inspect the respirator and ensure both head straps are untwisted.

1. Position the respirator in the palm of the hand with the nose section towards the fingertips and the head straps over the back of the hand.
2. Open the upper and lower panels and form a bend in the foam nose seal.
3. Place the lower panel beneath the chin and position the upper panel and foam nose seal over the bridge of the nose.
4. Holding the respirator in position, place the upper untwisted head strap over the head and onto the crown.
5. Draw the lower untwisted strap over the head and position it below the ears around the back of the neck. Do not cross the head straps.
6. Using both hands, mould the foam nose seal around the nose bridge and cheeks to achieve a close fit.
7. Cover the front of the respirator with both hands and inhale and exhale sharply to perform a fit check.
8. If air leaks around the nose or cheeks, readjust the foam nose seal.
9. If air leaks around the respirator edge, adjust the head straps and reposition the respirator.
10. Do not enter the work area unless a successful fit check can be achieved.

When removing a potentially contaminated respirator, avoid touching the respirator body. Remove it using the head straps, dispose of it appropriately and clean your hands.

Warnings & use limitations

Do not use for

Storage

Store unused TRIDENT Pink P2 Valved respirators in their original individual packaging and outer box in a clean, cool and dry environment. Protect from contamination, excessive moisture, direct sunlight, extreme temperatures and physical damage. Check any expiry date and specific storage conditions printed on the current product packaging before use.

Specifications

BrandTRIDENT®
ProductFlat Fold P2 Pink Valved Respirator
Product codeRTCFFP2VP
Product typeValved particulate respirator
ColourPink
Respirator classificationP2
Respirator standardAS/NZS 1716:2012
Certification ID for TRIDENT P2 valved respirator familyBMP 732382
Respirator styleThree-panel flat fold
Head attachmentHeadbands
Exhalation valveYes
Nose sealProprietary adjustable foam nose seal
Filtration constructionAdvanced multilayer technology
Suitable particulate types stated for the productDusts, mists, fumes and smoke
LatexLatex free
Individual packagingYes
Individual batch numberingYes
Retail pack sizeBox of 20

Frequently asked questions

Is the TRIDENT Pink respirator a P2 respirator?

Yes. The Pink model belongs to TRIDENT's P2 valved respirator range. TRIDENT's P2 valved respirator platform is certified to AS/NZS 1716:2012.

How many respirators are in a box?

Each HMS box contains 20 Pink TRIDENT respirators.

What is the product code for the Pink respirator?

Australian supplier Industree Group identifies the TRIDENT Flat Fold P2 Pink Valved Respirator as product code RTCFFP2VP.

Does the Pink TRIDENT respirator have an exhalation valve?

Yes. The respirator has an exhalation valve designed to reduce heat and moisture build-up within the breathing zone.

Is the Pink respirator different from the standard TRIDENT P2 Valved respirator?

The Pink model uses the same general TRIDENT P2 valved respirator design and technology but is supplied in a distinctive pink colour. HMS treats it as a separate product so customers specifically wanting the Pink respirator can order it directly.

Does the Pink respirator have a foam nose seal?

Yes. It uses a proprietary adjustable foam nose seal designed to assist facial sealing and help reduce eyewear fogging.

Can it help reduce glasses fogging?

TRIDENT states that the adjustable foam nose seal is designed to support an effective facial seal and reduce eyewear fogging.

Is the Pink TRIDENT respirator latex free?

Yes. Product information identifies the respirator as latex free.

Are the respirators individually packaged?

Yes. Each respirator is individually batch numbered and packaged for hygiene, portability and traceability.

What particles is the respirator designed for?

The multilayer filtration technology is designed for suitable mechanically and thermally generated particulates including dusts, mists, fumes and smoke.

Does the Pink respirator protect against gases or vapours?

Protection against gases or vapours should not be assumed. This is a P2 particulate respirator and must be selected according to the specific hazard and manufacturer limitations.

Can facial hair affect the fit?

Yes. Facial hair within the sealing area can prevent an adequate seal. Tight-fitting respirators should seal directly against the wearer's skin.

Do I need to perform a fit check?

Yes. A fit check should be performed every time the respirator is fitted. If an adequate seal cannot be achieved, the wearer should not enter the hazardous area.

Is the Pink respirator Level 3 fluid resistant?

HMS does not currently claim AS 4381 Level 3 certification for this exact Pink model because the available exact-product documentation does not establish that classification. Customers requiring a verified P2 Level 3 surgical respirator should select a product specifically certified for that requirement.

What is the difference between HMS-010 and HMS-011?

Both are valved P2 respirators from TRIDENT. HMS-011 is the distinctive Pink flat-fold P2 valved respirator sold as a standalone box of 20, while HMS-010 is the standard P2 valved product family offered by HMS with multiple fitting options.

Important product information

Respirator selection, fit and use depend on the hazard, workplace conditions and the wearer. Read and follow the manufacturer’s instructions supplied with the product. Where respiratory protection is required for work, follow the applicable workplace respiratory protection program and fit-testing requirements.