Trident

Trident P2 Valved Disposable Respirator - Box of 20

SKU: HMS-010

From $99.95 incl. GST

Trident P2 valved three-panel respirator with an exhalation valve to reduce heat and moisture build-up, adjustable foam nose seal, low breathing resistance and individually packaged respirators. Box of 20.

Key features

  • Certified P2 particulate respirator
  • AS/NZS 1716:2012 certified
  • Exhalation valve helps reduce heat and moisture build-up
  • Advanced multilayer particulate filtration technology
  • Suitable for protection against appropriate dusts, mists, fumes and smoke within manufacturer limitations
  • Three-panel flat-fold construction
  • Three-panel design provides structural integrity and a form-fitting seal
  • Proprietary adjustable foam nose seal
  • Foam nose seal helps reduce eyewear fogging
  • Low breathing resistance
  • Versatile unisex fit
  • Designed to accommodate a range of facial shapes and sizes
  • Headband fitting system
  • Small size available
  • Regular size available
  • Regular available with extended length head straps
  • XX Large size available
  • Latex free
  • Designed for use with other appropriate PPE
  • Individually batch numbered
  • Individually packaged
  • Box of 20

Product information

The Trident P2 Valved Disposable Respirator is a close-fitting three-panel respirator designed for protection against suitable mechanically and thermally generated particulates including dusts, mists, fumes and smoke. Its exhalation valve is designed to reduce heat and moisture build-up within the breathing zone, making the respirator particularly useful where wearer comfort is important during physically demanding or warmer working conditions. The three-panel construction provides structural integrity while allowing the respirator to conform to the face, and Trident's proprietary adjustable foam nose seal assists facial sealing while helping reduce eyewear fogging. The respirator uses head straps, offers low breathing resistance and is latex free. Each respirator is individually batch numbered and packaged. HMS sells this product in boxes of 20 with Small, Regular, Regular Extended Length Head Strap and XX Large options.

BrandTrident
Product typeP2 valved particulate respirator
Pack sizeBox of 20
StyleThree-panel flat-fold / headband / valved
Store SKUHMS-010
Packed weightTo be confirmed

Standards & classification

The Trident P2 Valved Disposable Respirator is certified to AS/NZS 1716:2012 as a P2 respirator.

Trident identifies certification ID BMP 732382 for this product family.

The manufacturer's dedicated P2 Valved Disposable Respirator information is the primary certification source used by HMS for this product.

Some Australian distributor material additionally describes particular valved Trident products using Level 3 and ARTG terminology. HMS has not incorporated those additional healthcare and fluid-resistance claims into the primary certification description for HMS-010 because Trident's dedicated valved product information verifies AS/NZS 1716:2012 P2 certification for this product family.

P2 is the verified Australian respirator classification used by HMS for this product.

Fit & sizing guidance

HMS offers the Trident P2 Valved Disposable Respirator in Small, Regular, Regular with Extended Length Head Straps, and XX Large options.

The Regular Extended Length Head Strap version retains the Regular respirator size but provides additional head-strap length.

Correct respirator selection and fit are important. The three-panel design is intended to provide a form-fitting seal while accommodating a range of facial shapes and sizes. The proprietary adjustable foam nose seal should be carefully moulded around the nose bridge and cheeks.

A close facial seal is essential for effective respiratory protection. Facial hair within the sealing area can interfere with the seal. Trident recommends that wearers be clean-shaven where the respirator contacts the face.

A fit check should be performed every time the respirator is fitted. Trident recommends fit testing in accordance with AS/NZS 1715:2009 and applicable workplace requirements.

Directions for use

Always read and follow the current Trident wearer instructions.

Before fitting, inspect the respirator and ensure both head straps are untwisted.

1. Select the appropriate HMS size or strap variant.
2. Position the respirator in the palm of the hand with the nose section towards the fingertips and the head straps over the back of the hand.
3. Open the upper and lower panels and form a bend in the foam nose seal.
4. Place the lower panel beneath the chin and position the upper panel and foam nose seal over the bridge of the nose.
5. Holding the respirator in position, place the upper untwisted head strap over the head and onto the crown.
6. Draw the lower untwisted strap over the head and position it below the ears around the back of the neck. Do not cross the head straps.
7. Using both hands, mould the foam nose seal around the nose bridge and cheeks to achieve a close fit.
8. Perform a fit check by covering the front of the respirator with both hands and inhaling and exhaling sharply.
9. If air leaks around the nose or cheeks, readjust the foam nose seal.
10. If air leaks around the respirator edge, adjust the head straps and reposition the respirator.
11. Do not enter the work area unless a successful fit check can be achieved.

When removing a potentially contaminated respirator, avoid touching the respirator body. Remove it using the head straps, dispose of it appropriately and clean your hands.

Warnings & use limitations

Do not use for

Storage

Store unused Trident P2 Valved respirators in their original individual packaging and outer box in a clean, cool and dry environment. Protect the respirators from contamination, excessive moisture, direct sunlight, extreme temperatures and physical damage. Check any expiry date and specific storage conditions printed on the current Trident packaging before use.

Specifications

BrandTrident
ProductP2 Valved Disposable Respirator
Product typeValved particulate respirator
Respirator classificationP2
Respirator standardAS/NZS 1716:2012
Certification IDBMP 732382
Available HMS variantsSmall, Regular, Regular Extended Length Head Strap, XX Large
Respirator styleThree-panel flat fold
Head attachmentHeadbands
Extended strap optionRegular size available with extended length head straps
Exhalation valveYes
Nose sealProprietary adjustable foam nose seal
Filtration constructionAdvanced multilayer technology
Suitable particulate types stated by manufacturerDusts, mists, fumes and smoke
LatexLatex free
Individual packagingYes
Individual batch numberingYes
Retail pack sizeBox of 20
Manufacturer inner quantity20 respirators
Manufacturer carton quantity240 respirators

Frequently asked questions

Is the Trident P2 Valved respirator P2 certified?

Yes. Trident identifies the P2 Valved Disposable Respirator as certified to AS/NZS 1716:2012 with certification ID BMP 732382.

How many respirators are in a box?

Each HMS box contains 20 individually packaged respirators.

What fitting options are available?

HMS offers Small, Regular, Regular with Extended Length Head Straps, and XX Large options.

What is the Regular Extended Length Head Strap option?

It uses the Regular respirator size with longer head straps. HMS presents it as a separate variant so customers can select the required configuration directly.

What does the exhalation valve do?

Trident states that the valved design reduces the build-up of heat and moisture within the breathing zone, which can improve wearer comfort.

Does the valve make the respirator easier to wear in warm conditions?

The valve is designed to reduce heat and moisture build-up inside the respirator, which may improve wearer comfort in warm environments or during physical activity.

Does the Trident P2 Valved respirator have a nose seal?

Yes. It uses a proprietary adjustable foam nose seal designed to assist facial sealing and reduce eyewear fogging.

Can the respirator help reduce glasses fogging?

Trident states that the adjustable foam nose seal is designed to help achieve an effective facial seal and reduce eyewear fogging.

Are the respirators individually packaged?

Yes. Trident states that each respirator is individually batch numbered and packaged for traceability, portability and hygiene.

Is the Trident P2 Valved respirator latex free?

Yes. Trident identifies the product as latex free.

What particles is the respirator designed for?

Trident states that its multilayer technology provides protection against appropriate mechanically and thermally generated particulates including dusts, mists, fumes and smoke.

Does the respirator protect against gases or vapours?

Protection against gases or vapours should not be assumed. This is a P2 particulate respirator and must be selected according to the specific hazard and manufacturer limitations.

Can facial hair affect the fit?

Yes. Facial hair within the sealing area can prevent an adequate facial seal. Trident recommends that the wearer be clean-shaven where the respirator seals against the face.

Do I need to perform a fit check?

Yes. A fit check should be performed every time the respirator is fitted and the wearer should not enter the work area if a successful seal cannot be achieved.

What is the difference between HMS-009 and HMS-010?

HMS-009 is the unvalved Trident P2 Level 3 Surgical Respirator family. HMS-010 is the Trident P2 Valved Disposable Respirator family and incorporates an exhalation valve designed to reduce heat and moisture build-up.

Important product information

Respirator selection, fit and use depend on the hazard, workplace conditions and the wearer. Read and follow the manufacturer’s instructions supplied with the product. Where respiratory protection is required for work, follow the applicable workplace respiratory protection program and fit-testing requirements.